Cathodic Protection 1 - Tester Exam Prep
Free practice questions

Free CP1 Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The CP1 exam has 100 questions and runs 3 hours.

These 10 free CP1 questions are organized by exam domain, so you can see how each part of the Cathodic Protection 1 - Tester blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Fundamentals of Corrosion (30-40%)

Question 1

A magnesium anode is bonded to a buried steel water line, and protective current is flowing. In the metallic bond wire, which way do electrons travel, and where does the oxidation supplying those electrons occur?

Show answer & explanation

Correct answer: A - Magnesium to steel; oxidation occurs at the magnesium.

Question 2

A CP supervisor is considering a higher rectifier setting for an underprotected pipe segment. The source has adequate spare capacity, its polarity is correct, and the metallic circuit is continuous. Which finding makes an output increase alone least likely to restore protection at the affected steel?

Show answer & explanation

Correct answer: B - Impermeable, disbonded wrap encloses wet steel at the corrosion site.

Question 3

Consider an oxygen-concentration cell on an unprotected carbon-steel tank floor. A sediment-covered area has little dissolved oxygen, while an adjacent bare area is well aerated; the steel and water provide continuous electrical paths. Which location-and-reaction pairing identifies the anodic metal-loss process?

Show answer & explanation

Correct answer: B - Sediment-covered steel; iron oxidation.

Domain 2: Equipment and Equipment Management (5-15%)

Question 4

A rectifier has a verified output of 6 A. A technician zeros a DC-capable clamp meter away from the cables, then closes its jaws around both the positive and negative output conductors. The clamp indicates approximately zero. How should the discrepancy be resolved?

Show answer & explanation

Correct answer: D - Repeat the measurement around one DC output conductor.

Question 5

Before a soil survey, a portable saturated copper/copper-sulfate reference electrode passes its comparison check. Its copper element is clean, its porous junction is wet, and clean undissolved copper-sulfate crystals remain at the bottom, clear of the junction. Which servicing decision is appropriate?

Show answer & explanation

Correct answer: A - Retain the crystals; they help maintain solution saturation.

Domain 3: Installation and Field Measurement (40-50%)

Question 6

All current sources affecting a buried carbon-steel pipeline are interrupted together. A checked copper/copper-sulfate electrode remains in the same position. The readings are -1.24 V with current ON, -0.79 V immediately after the switching transient, and -0.66 V after prolonged depolarization. The specified acceptance criterion is a polarized potential at least as negative as -0.85 V. Which result belongs in the polarized-potential assessment?

Show answer & explanation

Correct answer: C - -0.79 V; the specified criterion is not met.

Question 7

At a resistive bond between Pipelines East and West, a shunt is rated 50 mV at 25 A. A DC millivoltmeter reads -18 mV with its red lead on the East end of the shunt and its black lead on the West end. Determine the conventional current through the bond.

Show answer & explanation

Correct answer: A - 9 A from West to East.

Question 8

Two pipe sections separated by an insulating joint both read -0.93 V with their CP sources ON. During an authorized test, only the source serving the west section is interrupted. Sound test leads and one fixed nearby reference show the west section repeatedly shifting to -0.72 V while the east section stays at -0.93 V. Local electrolyte-gradient changes are negligible. What does the different response establish about the initial short-circuit suspicion?

Show answer & explanation

Correct answer: C - The response supports isolation; equal ON readings alone did not prove a short.

Question 9

Four Wenner probes are installed along a straight line at the 0, 3, 6, and 9 m marks. Each is driven only 0.10 m into the soil. Away from buried metallic interference, a valid four-terminal resistance reading is 4.0 ohms. Approximately what apparent soil resistivity should be recorded in ohm-centimeters?

Show answer & explanation

Correct answer: C - 7,540 ohm-centimeters.

Domain 5: Safety (1-10%)

Question 10

Beneath an energized transmission line, a crew is preparing to open a pipeline bond. The CP rectifier is locked out, but a safely obtained pipe-to-earth measurement remains 38 V AC rms. Site procedures prohibit this exposed-bond work at 15 V AC rms or above without approved electrical hazard controls, which are not in place. What is the appropriate immediate response?

Show answer & explanation

Correct answer: B - Keep the bond intact and stop the task pending approved electrical controls.

The rest of the CP1 blueprint

The CP1 exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more CP1 questions with explanations.

Continue in the free practice test →

View plans